Life test in vacuum carried out on Honeywell microswitch 11H30-REL-PGM
Combined vacuum, temperature and motion
Specific test development that includes external vacuum linear motion feed-through with controlled displacement.
Test details
- Continuous monitoring of electrical characteristics and temperature
- Motion cycles: 511210 cycles
- Temperature: -165°C